7.11 Reflexor
3. Adjust the Noise Level cursor, if required, by pressing the <+> key to increase or <-> key
4. Press the <Down Arrow> from Noise Level to advance to the High Limit cursor control. The
5. Press the <Down Arrow> from High Limit to advance to the Low Limit cursor control. The
6. Press the <Down Arrow> from Low Limit to advance to the Carrier FX control. The <+> and
7. Press the <Down Arrow> from Carrier FX to advance to the Diagnostic Data Display. The
8. To exit the Spectra Graph, press the <Menu> key.
9. To display the Digital Flow Display, press the <Menu> key from any Installation Menu
Available Spectra Graph Adjustments
Adjustment
Noise Level Set
High Limit
Low Limit
Carrier Fx
Reflexor Diagnostic Data
The [Diagnostic Data] menu and the [Application Info] sub menu screen provides one location
where all diagnostic data can be viewed.
Note
Adjustments can not be made on the [Application Info] menu screen. Adjustments can only
be made on the Spectra Graph.
106
to decrease.
Note
A delay in response to all keys will occur. This is due to the longer periodic sampling of
the keyboard by the processor while performing FFT's.
<+> and <-> key are active in this position. Refer to the "Available Adjustments To Spectra
Graph" table for details.
<+> and <-> keys are active in this position. Refer to the "Available Adjustments To Spectra
Graph" table for details.
<-> keys are active in this position.
<+> and <-> keys are active in this position.
location.
Function
Noise Filter
Low Pass Filter Setting
High Pass Filter
Transmit Frequency Code
Operating Instructions, 02/2010, A5E02951522A Revision 01
Notes
Set to approximately one quarter
the Peak FFT value for typical
flow conditions.
Set to two times the maximum
flow rate.
Set to one half minimum flow if
noise is present. In most cases,
leave at zero.
Adjust only under guidance of
technical support staff.