Programming Manual References
5.24 [3-9] PS Ring Group—
6.1 [4-1-1] Wired Extension—Extension Settings—Main—
6.10 [4-2-1] Portable Station—Extension Settings—Main—
Feature Manual References
9.1.1 ICD GROUP FEATURES
Delayed Ring
Specifies the delayed ringing setting of each member. (Applicable when the call distribution method of the
incoming call distribution group is set to Ring.)
Default
Immediate
Value Range
Immediate, 1–6 Rings, No Ring
Maintenance Console Location
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings—Member List
Programming Manual References
5.12 [3-5-1] Incoming Call Distribution Group—Group Settings—Main—
Feature Manual References
9.1.2 ICD Group Features—Group Call Distribution
Wrap-up Timer
Specifies the length of time that must pass after completing a call before the member extension can accept
another call.
This timer is used when "
5.15 [3-5-3] Incoming Call Distribution Group—Miscellaneous.
Default
0 s
Value Range
10 ´ n (n=0–300) s
Maintenance Console Location
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings—Member List
Programming Manual References
5.15 [3-5-3] Incoming Call Distribution Group—Miscellaneous—
Document Version 2009-12
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings—Member List
Group Name
Options—Wrap-up Timer based on" is set to "ICD Group Member" in
Extension Name
Extension Name
Distribution Method
Options—Wrap-up Timer based on
PC Programming Manual
497