6.17 [4-3] DSS Console
Ext. No. / Floating Ext. No. (for SDN)
Specifies the floating extension number of the PDN extension corresponding to the SDN button.
Note that the extension specified here must have a PDN button registered for the SDN button to function.
Default
Not stored.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
6.17 [4-3] DSS Console
Programming Manual References
None
Feature Manual References
13.1.7 PDN (Primary Directory Number)/SDN (Secondary Directory Number) Extension
Dial (for One-touch)
Specifies the number to be dialed. The PBX can have a maximum of 2000 One-touch Dialing buttons for
extensions and DSS Consoles.
Default
Not stored.
Value Range
Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
Maintenance Console Location
6.17 [4-3] DSS Console
Programming Manual References
None
Feature Manual References
12.1.4 One-touch Dialing
Dial (for NDSS)
Specifies the network extension number of the extension to be accessed using Network Direct Station
Selection.
Note that only extension numbers that have been previously registered in 11.4 [9-4] NDSS Key Table can be
specified here.