11-3] Power Failure Transfer - Panasonic KX-TDE100 Programming Manual

Ip-pbx
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

13.3 [11-3] Power Failure Transfer

When the power supply to the PBX fails, power failure transfer (PFT) switches the current connections to
Auxiliary Connections, so that certain SLTs and trunks can be connected. Auxiliary Connections allow trunk
calls to be made during a power failure. Up to 6 pairs of trunk cards and extension cards that are physically
connected by RJ11 cable can be specified. The conversations through the lines specified here will be
maintained even when the power returns.
For the KX-TDE600, select the shelf for which to set connections from the Shelf list. Note that PFT connections
can only be made within the same shelf.
Trunk Card Slot No.
Specifies the position of the trunk card to be used.
Value Range
None, 1–11
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Guide References
2.4.1 Power Failure Transfer
Extension Card Slot No.
Specifies the position of the extension card to be used.
Value Range
None, 1–11
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Guide References
2.4.1 Power Failure Transfer
13.3 [11-3] Power Failure Transfer
PC Programming Manual
955