10

Specifications

Items
Model
PROFIBUS-DP Data
Connector
Communications Speed 9.6 kbps to 12 Mbps
Ambient Temperature
Humidity
Storage Temperature
Area of Use
Altitude
YASKAWA ELECTRIC TOBP C730600 42D 1000-Series Option SI-P3 Installation Manual
Table 14 Option Specifications
SI-P3
• PROFIBUS-DP V0, V1
• PPO-TYPE: 1 to 5 (No. 3.072, Profile for Variable Speed Drives)
• Extended data 1
High-speed I/O data (inputs: 16 bytes, outputs: 16 bytes)
MEMOBUS/Modbus message (inputs: 16 byes, outputs: 16 bytes)
• Extended data 2
High-speed I/O data (inputs: 4 bytes, outputs: 4 bytes)
MEMOBUS/Modbus message (inputs: 8 bytes, outputs: 8 bytes)
• Basic data
High-speed I/O data (inputs: 6 bytes, outputs: 6 bytes)
9-pin D-sub connector (#4/40 UNC thread)
-10°C to +50°C (14°F to 122°F)
95% RH or lower with no condensation
-20°C to +60°C (-4°F to 140°F) allowed for short-term transport of the product
Indoor (free of corrosive gas, airborne particles, etc.)
1000 m (3280 ft.) or lower