Did-Rp2C Utility Screen - Icom id-rp2 Instruction Manual

Digital repeater system
Hide thumbs Also See for id-rp2:
Table of Contents

Advertisement

7
REPEATER SETTINGS
D
ID-RP2C utility screen
q File menu
The following sub menus are displayed when
clicked.
• Read from controller:
Reads the setting conditions from the ID-
RP2C.
• Write to controller:
Transfers and programs the displayed set-
ting conditions into the ID-RP2C.
• Restore factory default:
Resets to the default setting for all items.
• Exit: Quits the utility software.
w Option menu
The following sub menus are displayed.
• Network setup...:
The "Network setup" screen for IP address and
UDP port number entering for accessing the ID-
RP2C appears.
Enter the IP address of the ID-RP2C.
(Default: 172.16.0.1)
Click
Enter the UDP port number of the ID-RP2C.
(Default: 20319)
q
q
q
w
q
e
q
r
q
t
q
y
q
u
q
i
q
o
q
! 0
q
! 1
q
! 3
q
! 2
q
! 4
q
! 7
• Change Password...:
The "Change Password" screen for password
change for accessing the ID-RP2C.
Enter the current password. (Default: PASSWORD)
Click
Enter the new password again for confirmation.
IMPORTANT!: Enter the password using with
alphanumeric character
DO NOT forget the both IP address and password
setting. The access to the ID-RP2C through the
utility software will be impossible if forgotten.
e [Read]
Reads the ID-RP2C setting condition.
r [Write]
Transfers and programs the displayed setting con-
dition into the ID-RP2C.
39
q
! 5
q
! 6
q
! 8
q
! 9
q
@0
q
@1
q
@2
q
@3
Enter the new
password.
(case sensitive)
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Id- rp2

Table of Contents