Table 59:
CCU interrupt control register (TICR2 - address C9h) bit allocation
Bit
7
Symbol
TOIE2
Reset
0
Table 60:
CCU interrupt control register (TICR2 - address C9h) bit description
Bit Symbol
Description
0
TICIE2A
Input Capture Channel A Interrupt Enable Bit. If EA bit and this bit all be set, when a capture event is
detected, the program counter will vectored to the corresponding interrupt.
1
TICIE2B
Input Capture Channel B Interrupt Enable Bit. If EA bit and this bit all be set, when a capture event is
detected, the program counter will vectored to the corresponding interrupt.
2
-
Reserved for future use. Should not be set to logic 1 by user program.
3
TOCIE2A
Output Compare Channel A Interrupt Enable Bit. If EA bit and this bit are set to 1, when compare channel
is enabled and the contents of TH2:TL2 match that of OCRHA:OCRLA, the program counter will vectored
to the corresponding interrupt.
4
TOCIE2B
Output Compare Channel B Interrupt Enable Bit. If EA bit and this bit are set to 1, when compare channel
B is enabled and the contents of TH2:TL2 match that of OCRHB:OCRLB, the program counter will
vectored to the corresponding interrupt.
5
TOCIE2C
Output Compare Channel C Interrupt Enable Bit. If EA bit and this bit are set to 1, when compare channel
C is enabled and the contents of TH2:TL2 match that of OCRHC:OCRLC, the program counter will
vectored to the corresponding interrupt.
6
TOCIE2D
Output Compare Channel D Interrupt Enable Bit. If EA bit and this bit are set to 1, when compare channel
D is enabled and the contents of TH2:TL2 match that of OCRHD:OCRLD, the program counter will
vectored to the corresponding interrupt.
7
TOIE2
CCU Timer Overflow Interrupt Enable bit.

11. UART

The P89LPC938 has an enhanced UART that is compatible with the conventional 80C51
UART except that Timer 2 overflow cannot be used as a baud rate source. The
P89LPC938 does include an independent Baud Rate Generator. The baud rate can be
selected from the oscillator (divided by a constant), Timer 1 overflow, or the independent
Baud Rate Generator. In addition to the baud rate generation, enhancements over the
standard 80C51 UART include Framing Error detection, break detect, automatic address
recognition, selectable double buffering and several interrupt options.
The UART can be operated in 4 modes, as described in the following sections.

11.1 Mode 0

Serial data enters and exits through RXD. TXD outputs the shift clock. 8 bits are
transmitted or received, LSB first. The baud rate is fixed at

11.2 Mode 1

10 bits are transmitted (through TXD) or received (through RXD): a start bit (logic 0), 8
data bits (LSB first), and a stop bit (logic 1). When data is received, the stop bit is stored in
RB8 in Special Function Register SCON. The baud rate is variable and is determined by
the Timer 1 overflow rate or the Baud Rate Generator (see
generator and selection" on page
User manual
6
5
TOCIE2D
TOCIE2C
0
0
Rev. 03 — 7 June 2005
4
3
TOCIE2B
TOCIE2A
0
0
66).
UM10119
P89LPC938 User manual
2
1
-
TICIE2B
x
0
1
of the CPU clock frequency.
16
Section 11.6 "Baud Rate
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
0
TICIE2A
0
65 of 139

Advertisement

Table of Contents
loading

Table of Contents