Applicable Cables And Terminal Tightening Torque - Mitsubishi FX3U-4AD User Manual

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-1DA-BD (1-channel analog Output)
3G
3.2

Applicable Cables and Terminal Tightening Torque

Use the following cables to connect with the counterpart equipment. Terminate the cable end as shown below.
1. Cable
Applicable cable and tightening torque
0.3mm
Single-wire
(AWG22 to 20)
2-wire
0.3mm
0.3mm
Rod terminal
(AWG22 to 20)
with
(Refer to the rod terminal
insulation
external view shown in
sleeve
the following figure.)
2. Termination of cable end
To terminate the cable, treat the stranded/single wire directly or use a rod terminal with insulation sleeve.
• To directly terminate the end of a stranded/single-wire cable:
- Twist the end of the stranded cable so that the "barbed wires"
cannot protrude.
- Do not solder-plate the end of the cable.
• To terminate cable end using a rod terminal with insulation sleeve:
If the cable cover is too thick, it may be difficult to insert the cable into
the insulation sleeve. For this reason, select an appropriate cable while
referring to the external view.
Manufacturer
Phoenix Contact
3. Tool
• To tighten terminals, use a small-sized screwdriver whose head is straight and is not widened as shown in
the figure to the right.
Note:
If the diameter of screwdriver grip is too small, tightening torque will not
be able to be achieved. Use the following recommended screwdriver or
an appropriate replacement (grip diameter: approximately 25mm).
Manufacturer
Phoenix Contact
Wire size (stranded/
Tightening
single-wire)
torque
2
2
to 0.5mm
2
(AWG22)
0.22N•m to
2
2
to 0.5mm
0.25N•m
Model
AI 0.5-8WH
3.2 Applicable Cables and Terminal Tightening Torque
Termination
• To connect a stranded cable, peel the cover off the cable
and then twist the core before connection.
• To connect a single-wire cable, just peel the cover off the
cable before connection.
• Rod terminal with insulation sleeve
(recommended terminal)
AI 0.5-8WH : Manufactured by Phoenix Contact
• Caulking tool
CRIMPFOX ZA 3 : Manufactured by Phoenix Contact
(or CRIMPFOX UD 6 : Manufactured by Phoenix Contact)
Caulking tool
CRIMPFOX ZA 3
(or CRIMPFOX UD 6)
Model
SZS 0.4×2.5
3 Wiring
Termination of cable end
9mm
(0.35")
Insulation sleeve
Contact area
(Crimp area)
8mm
(0.31")
2.6mm
14mm
(0.1")
(0.55")
The head
should be
straight.
0.4mm
2.5mm
(0.09")
(0.01")
G-11
A
B
C
D
E
F
G
H
I
J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents