List Of Special Devices - Mitsubishi FX3U-4AD User Manual

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-4AD-PNK-ADP (4-channel Resistance Thermometer Data Input)
3U
4.2

List of Special Devices

If PNK-ADP is connected, special devices will be assigned automatically as shown in the following table:
• FX
, FX
3U
3UC
Special
device
M8260
Special
auxiliary
M8261
relay
M8262 to
M8269
D8260
D8261
D8262
D8263
D8264
Special
data
register
D8265
D8266
D8267
D8268
D8269
J-18
Series PLC
Device number
1st
2nd
3rd
M8270
M8280
M8271
M8281
M8272 to
M8282 to
M8279
M8289
D8270
D8280
D8271
D8281
D8272
D8282
D8273
D8283
D8274
D8284
D8275
D8285
D8276
D8286
D8277
D8287
D8278
D8288
D8279
D8289
Description
4th
M8290
Selects the temperature unit
M8291
Input sensor selection
M8292 to
Unused (Do not use.)
M8299
Channel-1 temperature measurement
D8290
data
Channel-2 temperature measurement
D8291
data
Channel-3 temperature measurement
D8292
data
Channel-4 temperature measurement
D8293
data
Averaging time for channel 1
D8294
(Setting range: 1 to 4095)
Averaging time for channel 2
D8295
(Setting range: 1 to 4095)
Averaging time for channel 3
D8296
(Setting range: 1 to 4095)
Averaging time for channel 4
D8297
(Setting range: 1 to 4095)
D8298
Error status
D8299
Model code = 11
4 Programming
4.2 List of Special Devices
R: Read / W: Write
Attribute
Refer to
Section
R/W
4.3
Section
R/W
4.4
-
-
R
R
Section
4.5
R
R
R/W
R/W
Section
4.6
R/W
R/W
Section
R/W
4.7
Section
R
4.8

Hide quick links:

Advertisement

Table of Contents
loading