H6: Pulse Train Input/Output

No.
(Addr.
Name
Hex)
Pulse Train Input
H6-01
Terminal RP Function
(042C)
Selection
H6-02
(042D) Pulse Train Input
Scaling
H6-03
(042E) Pulse Train Input Gain
H6-04
(042F)
Pulse Train Input Bias
H6-05
Pulse Train Input Filter
(0430)
Time
H6-06
Pulse Train Monitor
(0431)
Selection
H6-07
Pulse Train Monitor
(0432)
Scaling
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
LCD Display
All Modes
Enter CommandSel
0: Drive requires an Enter command before accepting any
0: Enter Required
changes to parameter settings.
1: No EnterRequired
1: Parameter changes are activated immediately without the
Enter command (same as V7).
Run CommandSel
All Modes
0: FWD Run &REV
0: FWD/Stop, REV/Stop
Run
1: Run/Stop, FWD/REV
1: Run & FWD/REV
All Modes
Selects operation when an attempt is made to write data into
EEPROM via MEMOBUS/Modbus communications and
Busy Enter Sel
writing into EEPROM is not possible.
0: No ROM Enter
There is normally no need to change this parameter from the
1: RAM Enter
default value
0: Cannot write into EEPROM
1: Write in RAM only
All Modes
Sets the filter time constant for monitoring the motor speed
from MEMOBUS/Modbus communications and
MtrSpd Monitor T
communication options.
Applicable MEMOBUS/Modbus registers are: 3EH, 3FH,
44H, ACH, and ADH
LCD Display
All Modes
Term RP Func Sel
0: Frequency reference
0: Frequency Ref
1: PID feedback value
1: PID Feedback
2: PID setpoint value
2: PID Set Point
3: V/f Control with Simple PG feedback (possible only when
3: PG Feedback
using motor 1 in V/f Control)
All Modes
Term RP Scaling
Sets the terminal RP input signal frequency that is equal to
100% of the value selected in H6-01.
All Modes
Terminal RP Gain
Sets the level of the value selected in H6-01 when a frequency
with the value set in H6-02 is input.
All Modes
Terminal RP Bias
Sets the level of the value selected in H6-01 when 0 Hz is input.
All Modes
Term RP Flt Time
Sets the pulse train input filter time constant.
All Modes
Select the pulse train monitor output function (value of the
Term MP Func Sel
o-oo part of Uo-oo).
For example, enter "501" for U5-01.
All Modes
Sets the terminal MP output signal frequency when the monitor
Term RP Scaling
value is 100%.
For example, to have the pulse train monitor output equal the
output frequency, set H6-06 to 102 and H6-07 to 0.
B.9 H Parameters: Multi-Function Terminals
Description
Description
Values
Page
Default: 0
620
Range: 0, 1
Default: 0
620
Range: 0, 1
Default: 0
620
Range: 0, 1
Default: 0 ms
Min.: 0
620
Max.: 100
Values
Page
Default: 0
306
Range: 0 to 3
Default: 1440 Hz
Min.: 100
307
Max.: 32000
Default: 100.0%
Min.: 0.0
307
Max.: 1000.0
Default: 0.0%
Min.: -100.0
307
Max.: 100.0
Default: 0.10 s
Min.: 0.00
307
Max.: 2.00
Default: 102
307
Range: 000 to 809
Default: 1440 Hz
B
Min.: 0
307
Max.: 32000
547