H1-oo
Function
Setting
External torque
78
reference polarity
inversion
Forward/reverse
detection
7E
(V/f Control with Simple
PG feedback)
PID Bi-Directional
7F
Enable
90 to 97 DriveWorksEZ
digital inputs 1 to 8
9F
DriveWorksEZ disabled DWEZ Disable
u

H2: Multi-Function Digital Outputs

No.
(Addr.
Name
Hex)
Terminal M1-M2
H2-01
function selection
(040B)
(relay)
Terminal M3-M4
H2-02
function selection
(040C)
(relay)
Terminal M5-M6
H2-03
function selection
(040D)
(relay)
H2-06
Power Consumption
(0437)
Output Unit Selection
H2-07
MEMOBUS Register 1
(0B3A)
Address Select
H2-08
MEMOBUS Register 1
(0B3B)
Bit Select
H2-09
MEMOBUS Register 2
(0B3C)
Address Select
H2-10
MEMOBUS Register 2
(0B3D)
Bit Select
<1> Available in drive software versions PRG: 1015 and later.
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
H1 Multi-Function Digital Input Selections
LCD Display
V/f
OLV/PM
Tref Sign Change
Open: Forward torque reference.
Closed: Reverse polarity.
V/f
PG Rotate Rev
OLV/PM
Direction of rotation detection (for V/f with Simple PG Feedback)
All Modes
PID BiDir Enable
Reserved.
All Modes
Reserved for DWEZ input functions
All Modes
Open: DWEZ enabled
Closed: DWEZ disabled
LCD Display
All Modes
M1-M2 Func Sel
Refer to H2 Multi-Function Digital Output Settings on pages
540
to
542
P1/PC Func Sel
P2/PC Func Sel
All Modes
Sets the units for the output signal when Power Consumption
Pulse Output or Regenerated Power Pulse Output are selected
as the digital output (H2-01, H2-02, or H2-03 = 39 or 3A).
Pwr Mon Unit Sel
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
All Modes
MFDO Regs1 Addr
Sets the addresses of the MEMOBUS/Modbus registers from
which data will be sent to contact outputs 62 and 162.
All Modes
MFDO Regs1 Bit
Sets the bits for the MEMOBUS/Modbus registers from which
data will be sent to contact outputs 62 and 162.
All Modes
MFDO Regs2 Addr
Sets the addresses of the MEMOBUS/Modbus registers from
which data will be sent to contact outputs 63 and 163.
All Modes
MFDO Regs2 Bit
Sets the bits for the MEMOBUS/Modbus registers from which
data will be sent to contact outputs 63 and 163.
B.9 H Parameters: Multi-Function Terminals
Description
V/f w PG
OLV
CLV
AOLV/PM
CLV/PM
V/f w PG
V/f w PG
OLV
CLV
AOLV/PM
CLV/PM
Description
for descriptions of setting values.
<1>
Page
287
287
287
287
Values
Page
Default: 0
287
Range: 0 to 192
Default: 1
287
Range: 0 to 192
Default: 2
287
Range: 0 to 192
Default: 1
297
Range: 0 to 4
Default: 1
Range: 1 to
298
1FFFH
Default: 0
Range: 0 to
298
FFFFH
Default: 1
Range: 1 to
298
1FFFH
Default: 0
Range: 0 to
298
FFFFH