U: Monitors; U: Monitors; U1: Operation Status Monitors - YASKAWA U1000 Technical Manual

Matrix drive low harmonic regenerative drive for industrial applications 200 v class: 7.5 to 75 kw (10 to 100 hp nd) 400 v class: 5.5 to 580 kw (7.5 to 775 hp nd)
Hide thumbs Also See for U1000:
Table of Contents

Advertisement

B.15 U: Monitors
B.15 U: Monitors
Monitor parameters allow the user to view drive status, fault information, and other data concerning drive operation.
u

U1: Operation Status Monitors

No.
(Addr.
Name
Hex)
U1-01
Frequency Reference
(0040)
U1-02
Output Frequency
(0041)
U1-03
Output Current
(0042)
U1-04
Control Method
(0043)
U1-05
Motor Speed
(0044)
U1-06
Output Voltage
(0045)
Reference
U1-07
Control Circuit Voltage DC Bus Voltage
(0046)
U1-08
Output Power
(0047)
U1-09
Torque Reference
(0048)
U1-10
Input Terminal Status
(0049)
572
All Modes
Frequency Ref
Monitors the frequency reference. Display units are determined
by o1-03.
All Modes
Output Freq
Displays the output frequency. Display units are determined by
o1-03.
All Modes
Output Current
Displays the output current.
All Modes
0: V/f Control
Control Method
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
V/f
V/f
OLV/PM
OLV/PM
Motor Speed
Displays the motor speed feedback. Display units are determined
by o1-03.
All Modes
Output Voltage
Displays the output voltage.
All Modes
Displays the control circuit voltage.
All Modes
Output kWatts
Displays the output power (this value is calculated internally).
V/f
V/f
Torque Reference
OLV/PM
OLV/PM
Monitors the internal torque reference.
All Modes
Displays the input terminal status.
U1 - 10= 00000000
Input Term Sts
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
Description
V/f w PG
V/f w PG
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
1
Digital input 1
(terminal S1 enabled)
1
Digital input 2
(terminal S2 enabled)
1
Digital input 3
(terminal S3 enabled)
1
Digital input 4
(terminal S4 enabled)
1
Digital input 5
(terminal S5 enabled)
1
Digital input 6
(terminal S6 enabled)
1
Digital input 7
(terminal S7 enabled)
1
Digital input 8
(terminal S8 enabled)
Analog
Unit
Output Level
10 V: Max
frequency
0.01 Hz
(-10 to +10 V)
10 V: Max
frequency
0.01 Hz
(-10 to +10 V)
10 V: Drive
<1> <2>
rated current
No signal output
available
10 V: Max
frequency
0.01 Hz
(-10 to +10 V)
10 V: 200 Vrms
0.1 Vac
<3>
10 V: 400 V
1 Vdc
<3>
<4>
10 V:
<5>
(-10 to +10 V)
10 V: Motor
rated torque
0.1%
(-10 to +10 V)
No signal output
available

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents