O4: Maintenance Monitor Settings - YASKAWA U1000 Technical Manual

Matrix drive low harmonic regenerative drive for industrial applications 200 v class: 7.5 to 75 kw (10 to 100 hp nd) 400 v class: 5.5 to 580 kw (7.5 to 775 hp nd)
Hide thumbs Also See for U1000:
Table of Contents

Advertisement

u

o4: Maintenance Monitor Settings

No.
(Addr.
Name
Hex)
o4-01
Cumulative Operation
(050B)
Time Setting
o4-02
Cumulative Operation
(050C)
Time Selection
o4-03
Cooling Fan Operation
(050E)
Time Setting
o4-05
Capacitor Maintenance
(051D)
Setting
DC Bus Pre-Charge
o4-07
Relay Maintenance
(0523)
Setting
o4-11
U2, U3 Initialization
(0510)
kWh Monitor
o4-12
Initialization
(0512)
Number of Run
o4-13
Commands Counter
(0528)
Initialization
o4-19
Power Unit Price
(113A)
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
LCD Display
All Modes
DrvElapsTimeCnt
Sets the value for the cumulative operation time of the drive in
units of 10 h.
All Modes
ElapsTimeCntSet
0: Logs power-on time
0: Power-On Time
1: Logs operation time when the drive output is active (output
1: Running Time
operation time).
All Modes
FanElapsTimeCn
Sets the value of the fan operation time monitor U4-03 in units
of 10 h.
All Modes
BusCap Maint Set
Sets the value of the Maintenance Monitor for the capacitors. See
U4-05 to check when the capacitors may need to be replaced.
All Modes
Sets the value of the Maintenance Monitor for the soft charge
ChrgCircMaintSet
bypass relay. See U4-06 to check when the bypass relay may need
to be replaced.
All Modes
Fault Data Init
0: U2-oo and U3-oo monitor data is not reset when the drive
0: Disabled
is initialized using A1-03.
1: Enabled
1: U2-oo and U3-oo monitor data is reset when the drive is
initialized using A1-03. Parameter is automatically reset to 0.
kWh Monitor Init
All Modes
0: No Reset
0: No action
1: Reset
1: Reset kWh data
All Modes
Run Counter Init
0: U4-02 monitor data is not reset when the drive is initialized
0: No Reset
using A1-03.
1: Reset
1: U4-02 monitor data is reset when the drive is initialized using
A1-03. Parameter is automatically reset to 0.
All Modes
Sets the price per 1 kWh to calculate the power rate displayed for
Energy Price/kWh
total consumed power (U9-07 to U9-10) and total regenerated
power (U9-11 to U9-14).
B.12 o: Operator-Related Settings
Description
Values
Page
Default: 0
Min.: 0
348
Max.: 9999
Default: 0
348
Range: 0, 1
Default: 0
Min.: 0
348
Max.: 9999
Default: 0%
Min.: 0
348
Max.: 150
Default: 0%
Min.: 0
349
Max.: 150
Default: 0
349
Range: 0, 1
Default: 0
349
Range: 0, 1
Default: 0
349
Range: 0, 1
Default: 000.00
Min.: 000.00
349
Max.: 650.00
B
565

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents