Advanced Diagnostics with the PROFIBUS Power Hub

7
Advanced Diagnostics with the PROFIBUS Power Hub
In conjunction with the Advanced Diagnostic Module HD2-DM-A, the
PROFIBUS Power Hub offers extensive analytic and monitoring possi-
bilities for a PROFIBUS fieldbus installation. This diagnosis, from now
on called "Advanced Diagnostics", covers, among other things:
proactive plant monitoring
analysis of the Fieldbus Physical Layer (jitter, noise etc.)
assistance during the complete fieldbus life cycle
wizards for commissioning and fault detection
integrated oscilloscope function
Further information regarding Advanced Diagnostics can be found in
the manual „Advanced Diagnostic Module HD2-DM-A". You can down-
load this manual from www.pepperl-fuchs.com.
7.1

Advanced Diagnostics Infrastructure

In general, the Advanced Diagnostics setup comprises a number of dif-
ferent hardware (PROFIBUS Power Hub, Advanced Diagnostic Module)
and software components (FDT, DTM). Depending on your require-
ments and your hardware and plant infrastructure, this setup can vary
(see also Advanced Diagnostic Module HD2-DM-A manual).
In order to integrate the Advanced Diagnostic Module HD2-DM-A into a
PROFIBUS Power Hub installation, two different setups can be imple-
mented:
direct connection via PROFIBUS DP (recommended) or
via the diagnostic bus of the Power Hub motherboard.
7.1.1

Advanced Diagnostics Connection via PROFIBUS DP

In the case of a direct connection of the diagnostic module, communi-
cation between the Diagnostic Manager (DTM) and the diagnostic mo-
dule takes place via PROFIBUS DP and the PROFIBUS Gateway HD2-
GTR-4PA. The Gateway in this case acts as an interface and a data ac-
cess coordinator for the diagnostic module.
No further components are necessary, the diagnostic module is being
addressed within the DTM using "Plug&Play". With this type of connec-
tion, one diagnostic module is statically assigned to one Gateway each.
Thus, this diagnostic module appears as a child node of its correspon-
ding PROFIBUS Gateway in the DTM project.
56
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com
P R O F I B U S P
O W E R
H
S
U B
E G M E N T
Copyright Pepperl+Fuchs, Printed in Germany
C
O U P L E R

Advertisement

Table of Contents
loading

Table of Contents