LVL-M1(H), LVL-M2(H)
Vibration Level Switch
ATEX, IEXEx
Ex ia IIC Ga
Instruction Manual
ISO9001

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs LVL-M1

  • Page 1 LVL-M1(H), LVL-M2(H) Vibration Level Switch ATEX, IEXEx Ex ia IIC Ga Instruction Manual ISO9001...
  • Page 2 Phone: +49 621 776 - 0 E-mail: info@de.pepperl-fuchs.com North American Headquarters Pepperl+Fuchs Inc. 1600 Enterprise Parkway Twinsburg, Ohio 44087 Phone: +1 330 425-3555 E-mail: sales@us.pepperl-fuchs.com Asia Headquarters Pepperl+Fuchs Pte. Ltd. P+F Building 18 Ayer Rajah Crescent Singapore 139942 Phone: +65 6779-9091 E-mail: sales@sg.pepperl-fuchs.com https://www.pepperl-fuchs.com...
  • Page 3: Table Of Contents

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Vibration Level Switch Vibracon LVL-M1(H), LVL-M2(H) Table of Contents Associated Documentation ..........
  • Page 4: Associated Documentation

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Associated Documentation This document is an integral part of the following documents: • KA00143O (LVL-M1, LVL-M2) • KA00144O (LVL-M1H, LVL-M2H) The documents which are supplied and correspond to the device type apply. Supplementary Documentation Electrical explosion protection literature: The literature can be found on the Internet at www.pepperl-fuchs.com.
  • Page 5: Extended Order Code

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Extended Order Code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated manual.
  • Page 6 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Device types LVL-M1, LVL-M1H, LVL-M2, LVL-M2H Basic specifications Probe version, probe length Position Option Description LVL-M1-XXX -XXXXXX-XX Compact LVL-M1H-XXX -XXXXXX-XX Compact, with temperature spacer Compact, with gastight spacer LVL-M2-XXX -XXXXXX-XX.XXXX BB, CB, DB in mm/inch, 1.4435/316L BE, CE, DE in mm/inch, 2.4610/Alloy C4...
  • Page 7: Safety Instructions: General

    • Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Pepperl+Fuchs. • The probe is made of stainless steel or high corrosion-resistant alloy of thickness 1 mm.
  • Page 8: Safety Instructions: Installation

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Safety Instructions: Installation Basic specification, feature Electrical connection, options SI, N1, N2 Figure 1 Zone 0 Tank; Zone 0 Electronic insert Housing Basic specification, feature Electrical connection, options SI, N1, N2: associated intrinsically safe power supply units...
  • Page 9 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Basic specification, feature Electrical connection, option PA Figure 2 Zone 0 Tank; Zone 0 Electronic insert Housing Permitted terminating resistor Ex ia IIC Certified associated apparatus Power supply Potential equalization • Connect the device using suitable cable and wire entries of protection type Intrinsic safety (Ex i).
  • Page 10 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Accessory sliding sleeve The sliding sleeve can be used for a continuous setting of the switch point (see manual). Intrinsic safety • The device is only suitable for connection to certified, intrinsically safe equipment with explosion protection Ex ia.
  • Page 11: Temperature Tables

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Temperature Tables Description notes Note Unless otherwise indicated, the positions always refer to the basic specification. General • 1st column: basic specification, feature Probe version, probe length • 2nd (1st) column: temperature classes T6 (85 °C) to T1 (450 °C) •...
  • Page 12 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Outside Zone 0 Outside Zone 0 Outside Zone 0 Figure 6 Basic specification, feature Electrical connection, option PA, SI LVL-M1, LVL-M1H: LVL-M2, LVL-M2H: T5...T1 BX, CX, DX LVL-M1, LVL-M1H: IX, QX LVL-M2, LVL-M2H: JX, KX, LX, RX, SX, T3...T1...
  • Page 13: Connection Data

    Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G Connection Data Basic specification, feature Electrical connection, option SI, N1, N2 Associated intrinsically safe power supply unit with max. electrical specifications below the characteristic values of the electronic inserts Electrical connection Electronic insert Supply...
  • Page 14 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G...
  • Page 15 Vibration Level Switch LVL-M1(H), LVL-M2(H) SI00064O-G...
  • Page 16 Pepperl+Fuchs Quality Download our latest policy here: www.pepperl-fuchs.com/quality SI00064O-G/98/A3/16.21 www.pepperl-fuchs.com © Pepperl+Fuchs · Subject to modifications Printed in Germany 114167 / DOCT-0558C...