Lenovo System x3650 M5 Installation And Service Manual page 461

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c.
RAID card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
• 80010204-1d09ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d09ffff or 0x800102041d09ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c.
RAID card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
• 80010204-1d0affff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2B Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d0affff or 0x800102041d0affff
Appendix A. Integrated management module II (IMM2) error messages
449

Advertisement

Table of Contents
loading

Table of Contents