Lenovo System x3650 M5 Installation And Service Manual page 245

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Figure 189. Cable connection
11. Replace the fan cage assembly (see "Replacing the fan cage assembly" on page 179).
12. Replace the top cover (see "Replacing the top cover" on page 151).
13. Slide the server into the rack.
14. Reconnect the power cords and any cables that you removed.
15. Turn on the peripheral devices and the server.
For the left EIA assembly
1. Read the safety information that begins on "Safety" on page v and "Installation guidelines" on page 297.
2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
3. Remove the top cover (see "Removing the top cover" on page 149).
4. Remove the fan cage assembly (see "Removing the fan cage assembly" on page 178).
5. Route the cable into the slot.
Figure 190. Cable routing
Front USB / operator
information panel cable
EIA assembly
.
Chapter 5
Installing, removing, and replacing components
233