Lenovo System x3650 M5 Installation And Service Manual page 331

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

PCI riser card type in riser-card assembly 1
Type 2
PCI riser-card assembly
Type 3
PCI riser-card assembly
To install the 4x 2.5-inch NVMe PCIe SSD upgrade kit in the server, complete the following steps.
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 297.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3.
Remove the cover (see "Removing the top cover" on page 149).
Step 4.
Remove the two 4-drive filler panels according to your configuration.
4-drive filler panel
Figure 290. Filler panels
Step 5.
To obtain more working room, remove the fan cage (see "Removing the fan cage assembly" on
page 178).
PCI riser card type in riser-card assembly 2
Type 5
PCI riser-card assembly
Slot 1, PCIe x8
Slot 2, PCIe x8
Slot 3, ML2
Type 6
PCI riser-card assembly
Slot 1, PCIe x16
Slot 3, PCIe x8
Chapter 5
Slot 6, PCIe x8
Slot 7, PCIe x8
Slot 8, PCIe x8
Slot 6, PCIe x16
Slot 8, PCIe x8
.
Installing, removing, and replacing components
NVMe adapter
installation
sequence
PCI slot 1, 2, 6,
7
PCI slot 3, 4, 5,
8
PCI slots 4 and
5 are on the
system board.
319

Advertisement

Table of Contents
loading

Table of Contents