Lenovo System x3650 M5 Installation And Service Manual page 175

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

You must turn off the server before installing simple-swap drives in the server. Before you install a
simple-swap SATA hard disk drive, read the following information. For a list of supported hard disk drives,
see http://www.lenovo.com/ serverproven/.
• Locate the documentation that comes with the hard disk drive and follow those instructions in addition to
the instructions in this chapter.
• As a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same
RAID array because it may lead to potential performance issues.
• Make sure that you have all the cables and other equipment that are specified in the documentation that
comes with the drive.
• Select the bay in which you want to install the drive.
• Check the instructions that come with the drive to determine whether you have to set any switches or
jumpers on the drive. If you are installing a SATA device, be sure to set the SATA ID for that device.
• The simple-swap server models support up to sixteen 2.5-inch or eight 3.5-inch simple-swap SATA hard
disk drives. Do not install hot-swap drives into a simple-swap server model, it is not supported.
• You can install one 2.5-inch simple-swap SATA hard disk drives in bay 0 in the server. Do not install
hot-swap drives into a simple-swap server model, it is not supported.
• The simple-swap server models are available only in non-RAID configurations.
• The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all
bays and PCI Express slots covered or occupied. When you install a drive or a PCI Express adapter,
save the EMC shield and filler panel from the bay or PCI Express adapter slot cover in the event that
you later remove the device.
To install a simple-swap hard disk drive, complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 297.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the filler panel from the empty drive bay.
Step 4.
Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
Step 5.
Install the hard disk drive in the drive bay. Align the drive assembly with the guide rails in the bay
and gently push the drive into the bay until the drive stops.
2.5-inch simple-swap
hard disk drive
Figure 93. 2.5-inch simple-swap hard disk drive installation
Filler panel handle
.
Chapter 5
Installing, removing, and replacing components
163

Advertisement

Table of Contents
loading

Table of Contents