Lenovo System x3650 M5 Installation And Service Manual page 729

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-040bffff : Array [ComputerSystemElementName] is in critical condition. (Drive 11)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d040bffff or 0x806f050d040bffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-040cffff : Array [ComputerSystemElementName] is in critical condition. (Drive 12)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d040cffff or 0x806f050d040cffff
Appendix A. Integrated management module II (IMM2) error messages
717

Advertisement

Table of Contents
loading

Table of Contents