REP 21 Motor Drive
Parts list on PL 8
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
Removal
1. Dis-assemble the control panel/scanner chassis assembly (REP 23).
2. Free the wires that supply the motor drive from their cable guide.
3. Remove the two mounting screws. Disconnect the grounding screw.
4. Remove the motor drive. Remove and keep the 44/18 gear.
Replacement
1. Unpack and visually inspect the new parts.
2. Attach the 44/18 gear on the motor drive.
3. Pass the wires in the wire guide. Connect the grounding screw in the original location.
4. Screw in and tighten the two mounting screws.
FaxCentre 2121/2121L
Motor drive
WARNING
Figure 1
11/06
Repairs and Adjustments
44/18 gear
44/18 gear
Mounting screws
4-43