v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 7871 and 1949," on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F030C Error
0x806F040C Information
Error Message
Memory device X (DIMM X
Status) memory scrub failed
[Note: X=1-16]
Group 1 (All DIMMs) memory
disabled
Action
1. Refer to TIP H21455 for minimum code level.
2. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
3. Manually re-enable all affected memory modules
if the server firmware version is older than UEFI
v1.10. If the server firmware version is UEFIv1.10
or newer, disconnect and reconnect the server to
the power source and restart the server.
4. Install the affected memory modules (as indicated
by the error LEDs on the system board or the
event logs) to a different memory channel or
microprocessor (see "Installing a memory
module" on page 64 for memory population
sequence).
5. If the error still occurs on the same memory
module, replace the affected memory module.
6. (Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector is damaged,
replace the system-board assembly (see
"Removing the system-board assembly" on page
94 and "Installing the system-board assembly" on
page 95).
7. (Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged pins.
If a damage is found, replace the system-board
assembly (see "Removing the system-board
assembly" on page 94 and "Installing the
system-board assembly" on page 95).
8. (Trained Service technician only) Replace the
affected microprocessor (See "Removing a
microprocessor and heat sink" on page 85 and
"Installing a microprocessor and heat sink" on
page 88).
1. If the memory module was disabled due to a
memory fault (error code 0x806F010C,
0x806F030C, or 0x806F050C), follow the procedure
for that event and restart the server.
2. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
re-enable the memory modules using the Setup
utility or the Advanced Settings Utility (ASU).
125