v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 7871 and 1949," on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F0207
Error
0x806F0207
Error
Error Message
Group 4, processor (all CPUs)
BIST failure
Group 4, processor (CPU X
Status) internal error [Note
X=1,2]
Action
1. Remove the blade server and ensure the
processors are installed correctly (see "Installing a
microprocessor and heat sink" on page 88).
2. Verify that the system is running the latest UEFI
firmware (see "Firmware updates" on page 33).
3. Run the Setup utility (see "Using the Setup
utility" on page 20).
a. Make sure that both processors are displayed
by the system.
b. Load the default settings.
c. Go to the System Settings menu and make
sure the processor is enabled.
4. If the problem continues, replace the processor
(see "Removing a microprocessor and heat sink"
on page 85 and "Installing a microprocessor and
heat sink" on page 88).
5. (Trained service technician only) If the error
continues, replace the system-board assembly (see
"Removing the system-board assembly" on page
94 and "Installing the system-board assembly" on
page 95).
1. Remove the blade server and ensure the
processors are installed correctly (see "Installing a
microprocessor and heat sink" on page 88).
2. Verify that the system is running the latest UEFI
firmware (see "Firmware updates" on page 33).
3. Run the Setup utility (see "Using the Setup
utility" on page 20).
a. Make sure that both processors are displayed
by the system.
b. Load the default settings.
c. Go to the System Settings menu and make
sure the processor is enabled.
4. If the problem continues, replace the processor
(see "Removing a microprocessor and heat sink"
on page 85 and "Installing a microprocessor and
heat sink" on page 88).
5. (Trained service technician only) If the error
continues, replace the system-board assembly (see
"Removing the system-board assembly" on page
94 and "Installing the system-board assembly" on
page 95).
123