IBM BladeCenter HS22V 7871 Problem Determination And Service Manual page 131

Hide thumbs Also See for BladeCenter HS22V 7871:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 7871 and 1949," on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F0021
Error
0x806F0107
Error
Error Message
System board, connector (PCIe
Status) fault
Group 4, processor (One of
CPUs) thermal trip
Action
1. Verify that you have the latest system firmware
(see "Firmware updates" on page 33).
2. If an expansion card is installed in the blade
server, verify that the firmware for each
expansion card is up to date.
3. Run the Setup utility and restore system setting to
defaults (see "Using the Setup utility" on page
20).
4. Check the event logs for other related error
messages (see "Error logs" on page 99).
5. Reseat any expansion cards that are installed in
the blade server (see "Removing an I/O
expansion card" on page 74 and "Installing an
I/O expansion card" on page 78).
6. Remove each expansion card, one at a time until
the error does not occur (see "Removing an I/O
expansion card" on page 74).
7. Replace failing adapter and reinstall any other
expansion cards that were removed (see
"Installing an I/O expansion card" on page 78).
8. (Trained service technician only) If the error
continues, replace the system-board assembly (see
"Removing the system-board assembly" on page
94 and "Installing the system-board assembly" on
page 95).
1. Make sure that the room temperature is within
the operating specifications (see "Features and
specifications" on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
4. Make sure that each bay of the BladeCenter unit
has either a device or a filler installed.
5. Make sure that the blade server is not missing
any heat sinks, DIMMs, heat-sink fillers, or DIMM
fillers (see Chapter 4, "Parts listing, Types 7871
and 1949," on page 41).
6. Make sure that the CPU heat sink is properly
attached to the CPU (see "Installing a
microprocessor and heat sink" on page 88).
7. (Trained service technician only) If the error still
occurs, replace the microprocessor. See "Removing
a microprocessor and heat sink" on page 85 and
"Installing a microprocessor and heat sink" on
page 88.
115
Chapter 6. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs22v 1949

Table of Contents