IBM BladeCenter HS22V 7871 Problem Determination And Service Manual page 133

Hide thumbs Also See for BladeCenter HS22V 7871:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 7871 and 1949," on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F010C Error
Error Message
Group 1 (All DIMMs)
uncorrectable ECC memory
error
Action
1. Refer to TIP H21455 for minimum code level.
2. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
3. Manually re-enable all affected memory modules
if the server firmware version is older than UEFI
v1.10. If the server firmware version is UEFIv1.10
or newer, disconnect and reconnect the server to
the power source and restart the server.
4. Install the affected memory modules (as indicated
by the error LEDs on the system board or the
event logs) to a different memory channel or
microprocessor (see "Installing a memory
module" on page 64 for memory population
sequence).
5. If the error still occurs on the same memory
module, replace the affected memory module.
6. (Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector is damaged,
replace the system-board assembly (see
"Removing the system-board assembly" on page
94 and "Installing the system-board assembly" on
page 95).
7. (Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged pins.
If a damage is found, replace the system-board
assembly (see "Removing the system-board
assembly" on page 94 and "Installing the
system-board assembly" on page 95).
8. (Trained Service technician only) Replace the
affected microprocessor (See "Removing a
microprocessor and heat sink" on page 85 and
"Installing a microprocessor and heat sink" on
page 88).
117
Chapter 6. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs22v 1949

Table of Contents