IBM BladeCenter HS22V 7871 Problem Determination And Service Manual page 140

Hide thumbs Also See for BladeCenter HS22V 7871:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 7871 and 1949," on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F0212
Error
0x806F020D Warning
124
BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide
Error Message
Group 4 (CPU Fault Reboot)
system hardware failure
Hard drive 1 (Drive 1 Status)
predictive failure
Action
No action is needed for this error code. This error
indicates a microprocessor fault and will reboot the
blade server up to three times to correct the error. If
the error continues, error codes 0x806F0007 and
0x806F0807 will be logged. Follow the corrective
actions for these error codes.
1. Replace the storage drive (see "Removing a SSD
storage drive" on page 61 and "Installing a SSD
storage drive" on page 62).
2. Make sure that the LSI controller firmware level is
up-to-date, upgrade if necessary; then, rerun the
test.
3. Make sure that the hard disk drive firmware level
is up-to-date, upgrade if necessary; then, rerun
the test.