Other Default; Rs-232C Default - Opticon OPI-3601 Specification Manual

2d imager scanner
Table of Contents

Advertisement

11.3. Other Default

Item
Read mode
Extended read time
Buzzer duration
Buzzer tone
Startup buzzer
Buzzer loudness
Buzzer timing
Good read LED indicator duration
Stand detection
Data buffering
[Data buffering]
Not all output data can be received depending on the host system. Therefore, it is recommended
to use buffered mode for USB-HID and Wedge PS/2 interfaces and Unbuffered mode for RS-
232C and USB-COM interfaces.
Unbuffered mode
@MENU_OPTO@ZZ@D80@ZZ@OTPO_UNEM@
[Stand detection]
Enable stand detection
@MENU_OPTO@ZZ@*4@ZZ@OTPO_UNEM@
* Refer to "OPI-3601 User's Manual" for supported commands.

11.4. RS-232C Default

Item
Baud rate
Parity bits
Data length
Stop bits
Handshaking
ACK/NAK
CTS time out
ACK/NAK time out
Command header
Command terminator
Response to the commands
Default Setting
Single read
Disable
75 ms
3 kHz
Enable
Loud (70%)
Before data transmission
200 ms
Disable
Buffered mode
Buffered mode (default)
@MENU_OPTO@ZZ@D81@ZZ@OTPO_UNEM@
Disable stand detection (default)
@MENU_OPTO@ZZ@*5@ZZ@OTPO_UNEM@
Default Setting
9600 bps
No parity
8 bits
1 bit
No handshake
ACK/NAK no response
Indefinitely
1 second
ESC or STX
CR or ETX
Disable
29
OPI-3601
Specifications Manual

Hide quick links:

Advertisement

Table of Contents
loading