7.6.

Pitch, Skew and Tilt

Pitch
: α = ±50°
Skew
: β = ±50°
Tilt
: γ = ±180°
<Conditions>
Bar Code Sample
Distance

Curvature

* For the pitch angle and tilt angle measurement, set the skew angle β = +15°
7.7.
Curvature
0.33 mm 12-digit UPC
0.15 mm 10-digit Codabar
<Conditions>
Bar Code Sample
Distance
Angle
Note: Scanning may fail due to the specular reflection of LED illumination when the reflectivity is high.
: 0.33 mm UPC specified in Chapter 7.1
: 105 mm from the front edge of the scanner
: R = ∞
Figure 6: Pitch, Skew and Tilt
: R ≧ 20 mm
: R ≧ 16 mm
: 0.33 mm UPC, 0.15 mm Codabar specified in Chapter 7.1
: 85 mm from the front edge of the scanner
: α = 0°, β =+15°, γ = 0°
Figure 7: Curvature