Lenovo Flex System x280 X6 Compute Node Installation And Service Manual page 87

Types 7903 and 4259
Hide thumbs Also See for Flex System x280 X6 Compute Node:
Table of Contents

Advertisement

202-000-000
MemStr Test Passed
Explanation: Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
202-801-000
MemStr Test Aborted
Explanation: Internal program error.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. If the system has stopped responding, turn off and restart the system.
5. Check the system firmware level and upgrade if necessary.
6. Run the memory diagnostic to identify the specific failing DIMM.
7. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
202-802-000
MemStr Test Aborted
Explanation: Memory size is insufficient to run the test. At least 1 GB is required.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
202-000-000 • 202-802-000
Chapter 6. Troubleshooting
75