806f090c-2028ffff • 806f090c-202affff
806f090c-2028ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: Memory has been Throttled.
May also be shown as 806f090c2028ffff or 0x806f090c2028ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
806f090c-2029ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: Memory has been Throttled.
May also be shown as 806f090c2029ffff or 0x806f090c2029ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
806f090c-202affff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: Memory has been Throttled.
May also be shown as 806f090c202affff or 0x806f090c202affff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
478
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide