806f0109-0701ffff • 806f010c-2001ffff
6. Replace the specified microprocessor.
806f0109-0701ffff
[PowerSupplyElementName] has been Power Cycled.
Explanation: The compute node Host Power has been powered off and powered on.
May also be shown as 806f01090701ffff or 0x806f01090701ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0108
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required. Host Power :
806f010c-200101ff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: An uncorrectable memory error has been detected.
May also be shown as 806f010c200101ff or 0x806f010c200101ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0138
SNMP Trap ID: 41
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
806f010c-2001ffff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: An uncorrectable memory error has been detected.
May also be shown as 806f010c2001ffff or 0x806f010c2001ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0138
SNMP Trap ID: 41
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.