S.3070007 • S.3828001
S.3070007
[S.3070007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System
halted
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
1.
2.
Reflash UEFI image.
3.
(Trained Service technician only) Replace the system board.
S.3108007
[S.3108007]
Explanation: The default system settings have been restored. System Configuration Restored to Defaults
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
S.3818004
[S.3818004]
Explanation: The CRTM flash driver could not successfully flash the staging area. A failure occurred. CRTM Update
Failed
Severity: Error
User response: Complete the following steps:
1.
Continue booting sytem. If system does not reset, manually reset the system.
2.
If the error is not reported on the subsequent boot, no additional recovery action is required.
3.
If the error persists, continue booting system and reflash UEFI image. Check whether there are any additional
instructions to update to this level of UEFI.
4.
(Trained Service technician only) Replace the system board.
S.3818007
[S.3818007]
Explanation: The firmware image capsules for both flash banks could not be verified. CRTM image capsule could
not be verified
Severity: Error
User response: Complete the following steps:
1.
If system failed to boot successfully, DC cycle system.
2.
If system boots to F1 steup, flash UEFI image and reset bank to primary (if required). If system boots without
error, recovery is complete and no additional action is required.
3.
(Trained Service technician only) If system fails to boot, or if flash attempt fails, replace the system board
S.3828001
[S.3828001]
Explanation: Boot Permission denied by Management Module: System Halted Boot Permission denied by
Management Module: System Halted
Severity: Error
User response: Complete the following steps:
1.
Check IMM log
2.
Review power policies and system configuration settings in the IMM.
658