806f000f-220101ff • 806f000f-220103ff
806f000f-220101ff
The System [ComputerSystemElementName] has detected no memory in the system.
Explanation: No memory was detected in the system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0794
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
806f000f-220102ff
Subsystem [MemoryElementName] has insufficient memory for operation.
Explanation: The usable Memory is insufficient for operation.
May also be shown as 806f000f220102ff or 0x806f000f220102ff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0132
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
806f000f-220103ff
The System [ComputerSystemElementName] encountered firmware error - unrecoverable boot
device failure.
Explanation: A System Firmware Error Unrecoverable boot device failure has occurred.
May also be shown as 806f000f220103ff or 0x806f000f220103ff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0770
SNMP Trap ID: 5
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.