Lenovo Flex System x280 X6 Compute Node Installation And Service Manual page 429

Types 7903 and 4259
Hide thumbs Also See for Flex System x280 X6 Compute Node:
Table of Contents

Advertisement

CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
806f050c-2581ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: The memory logging limit has been reached. All DIMMs. One of the DIMMs.
May also be shown as 806f050c2581ffff or 0x806f050c2581ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
806f050d-0400ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage.
May also be shown as 806f050d0400ffff or 0x806f050d0400ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response: Replace the hard disk drive 0 that is indicated by a lit status LED.
806f050d-0401ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage.
May also be shown as 806f050d0401ffff or 0x806f050d0401ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
806f050c-2581ffff • 806f050d-0401ffff
Chapter 6. Troubleshooting