Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
Related Links:
v
"Finding the UEFI diagnostic code" on page 648
80070221-1f0affff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a EXT QPI Link Error 2.
May also be shown as 800702211f0affff or 0x800702211f0affff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
80070301-030101ff
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Explanation: The microprocessor 1 temperature has risen above its specified threshold, causing a hard shutdown of
the node.
May also be shown as 80070301030101ff or 0x80070301030101ff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the microprocessor 1 heat sink is securely installed.
5. Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied.
6. Replace microprocessor 1.
80070221-1f0affff • 80070301-030101ff