Lenovo Flex System x280 X6 Compute Node Installation And Service Manual page 213

Types 7903 and 4259
Hide thumbs Also See for Flex System x280 X6 Compute Node:
Table of Contents

Advertisement

CIM Information: Prefix: IMM and ID: 0027
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
4000001c-00000000
Watchdog [arg1] Screen Capture Occurred.
Explanation: An operating-system error has occurred, and the screen capture was successful.
May also be shown as 4000001c00000000 or 0x4000001c00000000
Severity: Info
Alert Category: System - other
Serviceable: No
CIM Information: Prefix: IMM and ID: 0028
SNMP Trap ID: 22
Automatically notify Support: No
User response: If there was no operating-system error, complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
If there was an operating-system error, check the integrity of the installed operating system.
Related Links:
"Installing the LAN over USB Linux device driver" on page 58
v
"Installing the LAN over USB Windows device driver" on page 56
v
4000001d-00000000
Watchdog [arg1] Failed to Capture Screen.
Explanation: An operating-system error has occurred, and the screen capture failed.
May also be shown as 4000001d00000000 or 0x4000001d00000000
Severity: Error
Alert Category: System - other
Serviceable: No
CIM Information: Prefix: IMM and ID: 0029
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
6. Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster
solution before you update the code.