Advertisement

80070101-2c0101ff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified
threshold.
May also be shown as 800701012c0101ff or 0x800701012c0101ff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-2c01ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified
threshold.
May also be shown as 800701012c01ffff or 0x800701012c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-2c0201ff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 2 has exceeded its specified
threshold.
May also be shown as 800701012c0201ff or 0x800701012c0201ff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
80070101-2c0101ff • 80070101-2c0201ff
Chapter 6. Troubleshooting
257