8003010c-2581ffff • 8003010d-2b81ffff
8003010c-2581ffff
Sensor [SensorElementName] has asserted.
Explanation: IMM has reported a SMI Lane Failover.
May also be shown as 8003010c2581ffff or 0x8003010c2581ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
Related Links:
"Finding the UEFI diagnostic code" on page 648
v
8003010d-2101ffff
Sensor [SensorElementName] has asserted.
Explanation: IMM has lost communication with the eXFlash IPMI Proxy Service. The eXFlash DIMM device status
is unknown.
May also be shown as 8003010d2101ffff or 0x8003010d2101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: Check the status of the IPMI Proxy Service within the OS to ensure proper operation. Please refer to
the Intallation and Service Guide for the eXFlash IPMI Proxy Service that came with your eXFlash DIMM.
Related Links:
"Removing a flash DIMM" on page 730
v
"Installing a flash DIMM" on page 730
v
8003010d-2b81ffff
Sensor [SensorElementName] has asserted.
Explanation: IMM has lost communication with the eXFlash IPMI Proxy Service. The eXFlash DIMM device status
is unknown.
May also be shown as 8003010d2b81ffff or 0x8003010d2b81ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: Check the status of the IPMI Proxy Service within the OS to ensure proper operation. Please refer to
the Intallation and Service Guide for the eXFlash IPMI Proxy Service that came with your eXFlash DIMM.