80070217-2c03ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: The I/O expansion adapter in I/O expansion connector 3 has reported a fault.
May also be shown as 800702172c03ffff or 0x800702172c03ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070217-2c04ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: The I/O expansion adapter in I/O expansion connector 4 has reported a fault.
May also be shown as 800702172c04ffff or 0x800702172c04ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070219-0701ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: The system board has a critical fault.
May also be shown as 800702190701ffff or 0x800702190701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
80070217-2c03ffff • 80070219-0701ffff