Lenovo Flex System x280 X6 Compute Node Installation And Service Manual page 673

Types 7903 and 4259
Hide thumbs Also See for Flex System x280 X6 Compute Node:
Table of Contents

Advertisement

3.
(Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If
debris is found, remove debris. If socket is damaged, replace the system board first.
4.
(Trained Service technician only) If error recurs, replace the system board.
S.680B8
[S.680B8]
Explanation: Internal QPI Link Failure Detected.
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
(Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If
debris is found, remove debris. If socket is damaged, replace the system board first.
3.
(Trained Service technician only) If error recurs, replace the system board.
S.680B9
[S.680B9]
Explanation: External QPI Link Failure Detected.
Severity: Error
User response: Complete the following steps:
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
1.
(Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If
2.
debris is found, remove debris. If socket is damaged, replace the system board first.
(Trained Service technician only) If error recurs, replace the system board.
3.
W.3048006
[W.3048006]
Explanation: UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR) event.
Automated Boot Recovery, Booting Backup UEFI Image
Severity: Warning
User response: Complete the following steps:
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
1.
Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this product.
2.
3.
(Trained Service technician only) Replace the system board.
W.305000A
[W.305000A]
Explanation: An invalid date and time have been detected. RTC Date and Time Incorrect
Severity: Warning
User response: Complete the following steps:
1.
Check IMM/chassis event log. This event should immediately precede 0068002 error. Service that event or any
other battery related errors.
2.
Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS battery.
3.
If problem persists then check IBM support site for an applicable service bulletin or firmware update that applies
to this error.
4.
(Trained Service technician only) Replace the system board.
W.3058009
[W.3058009]
Explanation: DRIVER HEALTH PROTOCOL: Missing Configuraiton. Requires Change Settings From F1.
Severity: Warning
User response: Complete the following steps:
S.680B8 • W.3058009
Chapter 6. Troubleshooting
661