System Tests

Control Panel Tests

170 Part H: Diagnosing
The Service Kit can verify that the control panel controls are working.
The Control Panel form (Diagnose > System > Control Panel) lets you carry
out tests to verify that the controls on the front of the base station are working.
You need to be at the base station site to carry out these tests. The base station
can test all controls, including those used by the other channel.
To test control panel buttons
1. In the Button test area, click Start Test. This disables all control panel funct-
ions. The base station will now pass control panel inputs to the Service Kit.
2. Press a button on the control panel.
3. Check that the corresponding LED in the Service Kit form turns green.
4. Repeat steps 2 and 3 for each other button you want to test.
5. Click Stop Test to conclude the test.
To test the microphone's PTT button
1. In the Button test area, click Start Test. This disables all control panel
functions. The base station will now pass any control panel inputs to the
Service Kit.
2. Press the PTT button on the microphone.
3. Check that the PTT button LED in the Service Kit form turns green.
4. Click Stop Test to conclude the test.
To test the speaker
1. In the Speaker Test area, click Start Test.
2. Turn up the volume and listen to confirm that a 700 Hz test tone at 0 dBm
is coming from the speaker.
3. Click Stop Test to conclude the test.