Task Manager Inputs And Actions; Inputs; General Inputs - Tait TB8100 User Manual

Hide thumbs Also See for TB8100:
Table of Contents

Advertisement

Task Manager Inputs and Actions

Inputs

196 Part I: Task Manager
Task Manager has a large set of inputs and actions.
To select an input or action
Click in the appropriate box in the Task list item area. A menu with several
submenus appears.
The menu shows you the input relevant to the context from which you
accessed the Task Manager form. The submenus contain all the other inputs.
You can select any input.
To obtain Help on a task's input or action
1. Click the task.
2. In the Task list item area, click the Help icon beside the appropriate box.
An input is anything that Task Manager monitors. When the state of that input
changes from false to true, Task Manager executes tasks with that input. IF
NOT tasks are executed when the state of the input changes from true to false.
Most inputs are set to true when the base station transitions to Run mode.
Many inputs read the state of a system flag. Select Monitor > Monitoring >
Base Station to view the current state of system flags.

General Inputs

General inputs relate to the general operation of the base station.
Another receiver in rack
The Another receiver in rack input is true when there are two or more base
stations in the subrack and they are responding to polls on the internal bus. This
input is useful in combination with other inputs as a custom input.
Example
IF Another receiver in rack AND Battery voltage low
THEN Go to channel 2.
Another receiver in rack and Battery voltage low need to be combined
as a custom input, and Channel 2 can be set up with an extra low power output.
This example could be used to provide an extra low power output when there
are two base stations in the subrack. It could be used in a standard configuration
used by all base stations in a system and would not be processed in single base
stations.
Auxiliary supply enabled
The Auxiliary supply enabled input becomes true when Task Manager
turns the Auxiliary supply flag on. If the Auxiliary power control box is set to
Task Manager (Configure > Base Station > Miscellaneous), the auxiliary power
output is active.