Alarm status
AC in
Battery voltage
AC-DC converter
76 Part D: Monitoring
The first box in the form displays the name of the module: power management
unit.
The Alarm status box indicates whether there is a current alarm. If the LED is
red and the box displays 'Alarms active', one or more PMU alarms have been
triggered. Select Monitor > Alarms > Current Status to see which alarms are
active.
The AC in LED indicates the state of the AC power input into the AC-DC
converter.
LED
Text
Description
Green
On
AC power input is usable
Red
Off
AC power input is too low or too high
The battery voltage gauge indicates the voltage of the DC power supply to the
PMU (whether or not it is currently being used). The LED alongside indicates
the state of the power supply.
LED
Text
Description
Green
On
Battery input is usable. The PMU can provide up to 500 W
(or up to 40 W of power in low power mode).
Red
Off
Battery voltage is too low or too high.
Gray
Off
No battery power supply is fitted (the rectangle is also
disabled).
The LED in the AC-DC Converter submodule indicates the state of AC
power.
LED
Text
Description
Green
On
AC power input is usable
Red
Off
AC power input is too low or too high
Gray
Off
Mains Failure test is running
The submodule label indicates the voltage the DC-DC converter is designed
for (12, 24, or 48 V).