GE C30 Instruction Manual page 211

Controller system
Hide thumbs Also See for C30:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
The local and remote operation of each user-programmable pushbutton can be inhibited through the
and
settings, respectively. If local locking is applied, the pushbutton ignores set and reset commands
PUSHBTN 1 REMOTE
executed through the front panel pushbuttons. If remote locking is applied, the pushbutton ignores set and reset
commands executed through FlexLogic operands.
The locking functions are not applied to the autorestart feature. In this case, the inhibit function can be used in SBO control
operations to prevent the pushbutton function from being activated and ensuring "one-at-a-time" select operation.
The locking functions can also be used to prevent the accidental pressing of the front panel pushbuttons. The separate
inhibit of the local and remote operation simplifies the implementation of local/remote control supervision.
Pushbutton states can be logged by the event recorder and displayed as target messages. In latched mode, user-defined
messages can also be associated with each pushbutton and displayed when the pushbutton is on or changing to off.
— This setting selects the characteristic of the pushbutton. If set to "Disabled," the pushbutton is
PUSHBUTTON 1 FUNCTION
not active and the corresponding FlexLogic operands (both "On" and "Off") are de-asserted. If set to "Self-Reset," the
control logic is activated by the pulse (longer than 100 ms) issued when the pushbutton is being physically pressed or
virtually pressed via a FlexLogic operand assigned to the
When in "Self-Reset" mode and activated locally, the pushbutton control logic asserts the "On" corresponding FlexLogic
operand as long as the pushbutton is being physically pressed, and after being released the deactivation of the operand is
delayed by the drop out timer. The "Off" operand is asserted when the pushbutton element is deactivated. If the
pushbutton is activated remotely, the control logic of the pushbutton asserts the corresponding "On" FlexLogic operand
only for the time period specified by the
If set to "Latched," the control logic alternates the state of the corresponding FlexLogic operand between "On" and "Off" on
each button press or by virtually activating the pushbutton (assigning set and reset operands). When in the "Latched"
mode, the states of the FlexLogic operands are stored in a non-volatile memory. If power supply is lost, the correct state of
the pushbutton is retained upon subsequent power up of the relay.
— This setting specifies the top 20-character line of the user-programmable message and is intended to
PUSHBTN 1 ID TEXT
provide ID information of the pushbutton. See the User-definable Displays section for instructions on how to enter
alphanumeric characters from the keypad.
— This setting specifies the bottom 20-character line of the user-programmable message and is
PUSHBTN 1 ON TEXT
displayed when the pushbutton is in the "on" position. See the User-definable Displays section for instructions on entering
alphanumeric characters from the keypad.
— This setting specifies the bottom 20-character line of the user-programmable message and is
PUSHBTN 1 OFF TEXT
displayed when the pushbutton is activated from the on to the off position and the
This message is not displayed when the
implied to be "Off" upon its release. The length of the "Off" message is configured with the
PROPERTIES  FLASH MESSAGE TIME
— This setting specifies the time required for a pushbutton to be pressed before it is deemed active. This
PUSHBTN 1 HOLD
timer is reset upon release of the pushbutton. Note that any pushbutton operation requires the pushbutton to be pressed a
minimum of 50 ms. This minimum time is required prior to activating the pushbutton hold timer.
— This setting assigns the FlexLogic operand serving to operate the pushbutton element and to assert
PUSHBTN 1 SET
operand. The duration of the incoming set signal must be at least 100 ms.
PUSHBUTTON 1 ON
— This setting assigns the FlexLogic operand serving to reset pushbutton element and to assert
PUSHBTN 1 RESET
operand. This setting is applicable only if pushbutton is in latched mode. The duration of the incoming
PUSHBUTTON 1 OFF
reset signal must be at least 50 ms.
— This setting enables the user-programmable pushbutton autoreset feature. This setting is applicable
PUSHBTN 1 AUTORST
only if the pushbutton is in the "Latched" mode.
— This setting specifies the time delay for automatic reset of the pushbutton when in the
PUSHBTN 1 AUTORST DELAY
latched mode.
— This setting assigns the FlexLogic operand serving to inhibit pushbutton operation from the operand
PUSHBTN 1 REMOTE
assigned to the
PUSHBTN 1 SET
— This setting assigns the FlexLogic operand serving to inhibit pushbutton operation from the front panel
PUSHBTN 1 LOCAL
pushbuttons. This locking functionality is not applicable to pushbutton autoreset.
C30 CONTROLLER SYSTEM – INSTRUCTION MANUAL
PUSHBTN 1 SET
PUSHBTN 1 DROP-OUT TIME
PUSHBUTTON 1 FUNCTION
setting.
or
settings.
PUSHBTN 1 RESET
setting.
setting.
PUSHBUTTON 1 FUNCTION
is "Self-reset" as the pushbutton operand status is
PRODUCT SETUP  DISPLAY
PRODUCT SETUP
PUSHBTN 1 LOCAL
5
is "Latched."
5-93

Advertisement

Table of Contents
loading

Table of Contents