Replacing Rear System Fan

CAUTIONS
The system fan for the Intel
you must first take the workstation out of service, turn off all peripheral devices connected to the system, turn off the system
by pressing the power button, and unplug the AC power cord from the system or wall outlet.
1.
Observe the safety and ESD precautions listed in Appendix A, "Safety Information".
2.
Power down the workstation and unplug all peripheral devices and the AC power cable.
3.
Remove the left side cover. For instructions, see
4.
Remove the system fan duct. For instructions, see
5.
Disconnect the fan power cable from the workstation board (see letter "A" in the following figure). Remove the system fan
from its snap-in bracket by pressing the two bracket tabs outward (see letter "B").
Intel® Workstation System SC5650SCWS Service Guide
Figure 73. Locking Fixed Power Supply into Chassis
"Installing the Left Side
®
Worksation System SC5650SCWS is NOT hot swappable. Before removing or replacing a fan,
"Removing the Left Side
Cover".
Cover".
"Removing and Installing System Fan
Hardware Installations and Upgrades
Duct".