Protection Levels - Siemens SINUMERIK 808D ADVANCED Programming And Operating Manual

Operator-panel-based cncs
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

1.4

Protection levels

Overview
The SINUMERIK 808D ADVANCED provides a concept of protection levels for enabling data areas. Different protection
levels control different access rights.
The control system delivered by SIEMENS is set by default to the lowest protection level 7 (without password). If the
password is no longer known, the control system must be reinitialized with the default machine/drive data. All passwords are
then reset to default passwords for this software release.
Note
Before you boot the control system with default machine/drive data, make sure that you have backed up your machine/drive
data; otherwise, all data are lost after rebooting with default machine/drive data.
Protection level
0
1
2
3-6
7
Protection level 1
Protection level 1 requires a manufacturer password. With this password entry, you can perform the following operations:
● Entering or changing part of the machine data and drive data
● Conducting NC and drive commissioning
Protection level 3-6
Protection level 3-6 requires an end user password. With this password entry, you can perform the following operations:
● Entering or changing part of the machine data and drive data
● Editing programs
● Setting offset values
● Measuring tools
Protection level 7
Protection level 7 is set automatically if no password is set and no protection level interface signal is set. The protection level
7 can be set from the PLC user program by setting the bits in the user interface.
In the menus listed below the input and modification of data depends on the set protection level:
● Tool offsets
● Work offsets
● Setting data
● RS232 settings
● Program creation/program correction
The number of machine data and drive data which can be read or modified depends on the protection level. You can set the
protection level for these function areas with the display machine data (USER_CLASS...).
Setting password
You can set the desired password through the following operating area:
+
14
Locked by
Siemens password
Manufacturer password
Reserved
End user password
(Default password: "CUSTOMER")
No password
Area
Siemens, reserved
Machine manufacturers
End users
End users
Programming and Operating Manual (Milling)
6FC5398-4DP10-0BA1, 01/2014

Advertisement

Table of Contents
loading

Table of Contents