Connecting in hazardous area installations

Wiring setups for hazardous area installations
The following wiring options are available for hazardous area installations:
Non-incendive wiring (Canada)
In all cases, check the device label on your instrument, and confirm the approval rating.
1. Non-incendive wiring (Canada)
SITRANS LUT420
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
Power Rating: 100
230V
± 15%
50/60 Hz 36 VA (10 W)
Contact Rating: 1A/5A @ 250V
Non Inductive
Operating Temperature:
20°C to 50°C
Enclosure:
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class I I
159134
Per Drawing A5E03936871
Siemens Mi ltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
SITRANS LUT420
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
Power Rating: 10
32V
10W
Contact Rating: 1A/5A @ 250V
Non Inductive
Operating Temperature:
20°C to 50°C
Enclosure:
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class III
159134
Per DWG
A5E03936871
Siemens Mi ltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
CSA Class I, Div 2 connection drawing number A5E03936871 can be downloaded from the
product page of our website at www.siemens.com/sitransLUT400.
A5E33329501
SITRANS LUT430
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
Power Rating: 100
230V
50/60 Hz 36 VA (10 W)
Contact Rating: 1A/5A @ 250V
Operating Temperature:
Enclosure:
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class III
159134
Per Drawing A5E03936871
Siemens Milltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
SITRANS LUT430
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
Power Rating: 10
32V
Contact Rating: 1A/5A @ 250V
Operating Temperature:
Enclosure:
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class III
159134
Per DWG
A5E03936871
Siemens Milltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
SITRANS LUT440
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
± 15%
Power Rating: 100
Non Inductive
Contact Rating: 1A/5A @ 250V
20°C to 50°C
Operating Temperature:
Enclosure:
159134
Siemens Milltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
SITRANS LUT440
7MLxxxx xxxxx xxxx
Serial No : GYZ / B1034567
10W
Power Rating: 10
Non Inductive
Contact Rating: 1A/5A @ 250V
20°C to 50°C
Operating Temperature:
Enclosure:
159134
Siemens M lltronics Process Instruments Peterborough
Assembled in Canada with domestic and imported parts
230V
± 15%
50/60 Hz 36 VA (10 W)
Non Inductive
20°C to 50°C
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class III
Per Drawing A5E03936871
32V
10W
Non Inductive
20°C to 50°C
IP65 / TYPE 4X / NEMA 4X
Class I Div 2 Gr A B C & D T3C
Class II Div 2 Gr F & G
Class III
Per DWG
A5E03936871