1.1.3. QS Flow
Use this wizard to configure simple flow applications.
(Visible on LUT430 (Pump and Flow), and LUT440 (OCM) configured models only.
a.
Press RIGHT arrow
MENU.
b.
Press RIGHT arrow
c.
Press DOWN arrow
d.
At each step, press DOWN arrow
accept default values and move directly to
the next item,
or RIGHT arrow
current selection is highlighted.
e.
Scroll to desired item and press RIGHT arrow
to store the change, then press DOWN
arrow
to continue.
f.
At any time, you can press UP arrow
go back, or LEFT arrow
Start of QS
Flow Wizard
Select
PMD
- Primary Measuring
Device
Set
PMD dimensions
(vary by PMD)
- OCM Dimension 1
- OCM Dimension 2
- OCM Dimension 3
- OCM Dimension 4
A5E33329501
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
to activate PROGRAM mode and open menu level 1: MAIN
two times to navigate to menu item 1.1. 1 .
two times and RIGHT arrow
to
to open Edit mode: the
to
to cancel the wizard.
Select
transducer
- Transducer
Set
calculation method,
level units, and
setpoints
- Method of Flow
Calculation
- Units
- High Calibration Point
- Low Calibration Point
- Response Rate
Set
flow units and
calibration data
- Maximum Head
- Zero Head Offset
- Flowrate Units
- Maximum Flow at 20 mA
- Flowrate Decimal
- Low Flow Cutoff
to open QS Flow.
QUICK START FLOW
TRANSDUCER
XRS 5
BACK
CANCEL
EDIT
NEXT
QUICK START FLOW
TRANSDUCER
NO TRANSDUCER
XRS-5
XPS 10
XPS 15
XCT 8
XCT 12
Select
temperature
source
- Temperature Source
- Fixed Temperature
Set
calculation factors
(vary by PMD)
- Flow Exponent
- K Factor
- V-Notch Angle
- Slope
- Roughness Coefficient
Flow Wizard
complete
Page 47