Battery Resistance Measurement
Battery Resistance Measurement:
The X2 AC Pro has the ability to check your battery's total internal resistance,
highest total resistance, lowest total resistance and the resistance of each cell.
Simply connect the battery to the charger via the main battery lead to battery
socket and the balance wires to the balance socket as shown below.
BATT/PROGRAM
BATT RESISTANCE
ENTER/Start ► button to enter the battery resistance meter program.
012 005 005
006
TOTAL: mΩ
H:12mΩ
L:5mΩ
From the BATT/PROGRAM menu use the
to scroll to the BATT RESISTANCE program, press the
The first screen indicates each cell's internal resistance.
+
or ▬ buttons to view the packs total voltage
Press the
and the cell with the highest and lowest internal resistance.
+
or ▬ buttons