Operating Problems - Wexiodisk WD-90 DUO Installation And User Manual

Hide thumbs Also See for WD-90 DUO:
Table of Contents

Advertisement

Using the dishwasher

4.3.11 Operating problems

PROBLEM
No indication on the control
panel display when the con-
trol button is pressed.
The machine will not fill with
water.
The tanks will not stop filling
with water.
Noise from the wash pump.
The machine is not cleaning
properly.
Granules are sticking to the
washed items.
The granules end up in the
wrong tank.
Items do not dry.
Troubleshooting
CAUSE
The mains switch is off.
The shut-off tap on the in-
coming water supply is
closed.
The level pipe is not in place
in the tank.
The level pipe's rubber
sleeve is not sealing against
the bottom plate.
Low water level. Foam in the
tank.
See chapter "Check the wash result" on page 38.
The rinse nozzles are
blocked.
There is too much foam in the
machine.
The permanent strainer in the
tank has not been cleaned.
The cover plates and strainer
are not in place in the tank or
have been incorrectly fitted.
The rinse nozzles are
blocked.
When contacting the service company, the following details relating to the ma-
chine should be provided:
Machine type and model
Machine serial number and installation date
Short description of the fault/problem
What happened immediately before the fault occurred
WD-90 DUO
ACTION
Turn on the mains switch.
Open the tap.
Fit the level pipe.
Check that the level pipe is
closed. Change the rubber
sleeve if it is damaged.
Check the level. Change the
water.
Clean the nozzles.
Check to see how clean the
wash water is. Change the
water if necessary.
Clean the permanent strain-
er, see section "Cleaning the
inside of the machine" on
page 44
Fit cover plates and strain-
er(s). Check they are correct-
ly located and cover the tank.
Check and clean the nozzles.
51
Rev. 0 (201401)